How To Calibrate A CoolTouch Bar Valve
Shower valves are set to run at 38°C. However, there are many things that can affect this such as your own hot and cold-water temperatures, to rectify this is a relatively simple job that requires vey few tools.
- Remove the cover (1), unscrew the screw (2). The control knob (3) can now be
pulled off. - Turn the spindle (A) until the temperature is at the required level.
- Turn Anti-Clockwise hotter,
- Turn Clockwise cooler.
- Test again using a thermometer Control the right position of the stepped plastic
washer (4). - When water temperature is at the required level re-fit the control knob